Lighting
Lighting
-
Technical committeeTypeAcronymIEC 61347-2-9CommitteePublished year2012KeywordsDescription
IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".This publication is to be read in conjunction with IEC 61347-1:2007.
Technology -
Technical committeeTypeAcronymIEC 61347-2-8CommitteePublished year2000KeywordsDescription
This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. This consolidated version consists of the first edition (2000) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication. The contents of the corrigendum of August 2012 have been included in this copy.
Technology -
Technical committeeTypeAcronymIEC 61347-2-7CommitteePublished year2011KeywordsDescription
IEC 61347-2-7:2011+A1:2017 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7. This publication is to be read in conjunction with IEC 61347-1:2007. This consolidated version consists of the third edition (2011) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.Technology -
Technical committeeTypeAcronymIEC 61347-2-3CommitteePublished year2011KeywordsDescription
IEC 61347-2-3:2011+A1:2016 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating fromthe supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:
- rectifying test conditions when dimming;
- construction requirements;
- measurement circuits and limits for HF leakage currents;
- modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy. This consolidated version consists of the second edition (2011) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-14CommitteePublished year2018KeywordsDescription
IEC 61347-2-14:2018 specifies particular safety requirements for electronic controlgear for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating frequencies deviating from the supply frequency, associated with fluorescent induction lamps as specified in IEC 62532 and IEC 62639, for high-frequency operation.
Technology -
Technical committeeTypeAcronymIEC 61347-2-13CommitteePublished year2014KeywordsDescription
IEC 61347-2-13:2014+A1:2016 specifies particular safety requirements for electronic controlgear for use on d.c. or a.c. supplies up to 1 000 V (a.c. at 50 Hz or 60 Hz) and at an output frequency which can deviate from the supply frequency, associated with LED modules. Controlgear for LED modules specified in this standard are designed to provide constant voltage or current at SELV or higher voltages. Deviations from the pure voltage and current types do not exclude the gear from this standard. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) Replacement of the SELV-equivalent requirements by SELV requirements and reference to the SELV requirements of Annex L in IEC 61347-1:2007/AMD2:2012.
b) Reference to IEC 61347-1 for the protection against accidental contact with live parts, moisture resistance and insulation and electric strength.
c) New Annex J for emergency lighting requirements.This publication shall be read in conjunction with IEC 61347-1:2012. This consolidated version consists of the second edition (2014) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-12CommitteePublished year2005KeywordsDescription
IEC 61347-2-12:2005+A1:2010 specifies particular general and safety requirements for d.c. or a.c. supplied electronic ballasts. The supply comprises a.c. voltages up to 1000 V at 50 Hz/60 Hz. The type of ballast is an convertor that may contain igniting and stabilising elements for operation of a discharge lamp at d.c. or at a frequency that can deviate from the supply frequency. The lamps associated with the ballast are specified in IEC 60188 (High pressure mercury vapour lamps), IEC 60192 (Low pressure sodium vapour lamps), IEC 60662 (High pressure sodium vapour lamps), IEC 61167 (Metal halide lamps) and else for general purpose lighting. Ballasts for fluorescent lamps and for lamps for special applications like for theatre and for vehicles are excluded. The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. A vertical line in the margin shows where the base publication has been modified by amendment 1. Additions and deletions are displayed in red, with deletions being struck through. This consolidated version consists of the first edition (2005) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication.
This publication is to be read in conjunction with IEC 61347-1:2000.
Technology -
Technical committeeTypeAcronymIEC 61347-2-11CommitteePublished year2001KeywordsDescription
IEC 61347-2-11:2001+A1:2017, published in conjunction with IEC 61347-1, represents an editorial review of IEC 60920. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This part of IEC 61347 specifies general and safety requirements for miscellaneous electronic circuits used with luminaires for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and/or d.c. supplies up to 250 V. This part does not apply to circuits or devices for which specific IEC standards are published. This first edition of IEC 61347-2-11, together with IEC 61347-1, cancels and replaces the first edition of IEC 60920, published in 1990, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1. The contents of the corrigendum of December 2001 have been included in this copy. This consolidated version consists of the first edition (2001) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-10CommitteePublished year2000KeywordsDescription
IEC 61347-2-10: 2009 specifies particular requirements for electronic invertors and convertors for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to supply voltages not exceeding 1 000 V at 50 Hz or 60 Hz or 1 000 V d.c. This consolidated version consists of the first edition (2000) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-1CommitteePublished year2000KeywordsDescription
IEC 61347-2-1:2000+A1:2005+A2:2013 specifies particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and ballasts covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and IEC 61347-2-9. This consolidated version consists of the first edition (2000), its amendment 1 (2005) and its amendment 2 (2013). Therefore, no need to order amendments in addition to this publication.
This publication is to be read in conjunction with IEC 61347-1:2007
Technology