Auxiliaries for Lamps
-
Technical committeeTypeAcronymIEC 62386-220CommitteePublished year2019Description
IEC 62386-220:2019 specifies a bus system for control by digital signals of electronic lighting equipment which is in line with the requirements of IEC 61347 (all parts), with the addition of DC supplies.
This document is applicable to control gear supporting centrally supplied emergency operation as described in EN 50171.
This document does not apply to self-contained emergency lighting control gear. These types of control gear are specified in IEC 62386-202.Technology -
Technical committeeTypeAcronymIEC 62386-104CommitteePublished year2019Description
IEC 62386-104:2019 The IEC 62386 series specifies a bus system for control by digital signals of electronic lighting equipment. This part of IEC 62386 applies to a system with wireless or alternative wired communication between its units, instead of a wired bus system, where the meaning of “wireless or alternative wired communication”, or in short “telecommunication”, is any type of communication network different from the wired system described in IEC 62386-101.
Where the electronic lighting equipment is covered by the scope of IEC 61347 (all parts), it is in line with the requirements of IEC 61347 (all parts), with the addition of DC supplies.Technology -
Technical committeeTypeAcronymIEC 61347-2-9CommitteePublished year2012KeywordsDescription
IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".This publication is to be read in conjunction with IEC 61347-1:2007.
Technology -
Technical committeeTypeAcronymIEC 61347-2-8CommitteePublished year2000KeywordsDescription
This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. This consolidated version consists of the first edition (2000) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication. The contents of the corrigendum of August 2012 have been included in this copy.
Technology -
Technical committeeTypeAcronymIEC 61347-2-7CommitteePublished year2011KeywordsDescription
IEC 61347-2-7:2011+A1:2017 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7. This publication is to be read in conjunction with IEC 61347-1:2007. This consolidated version consists of the third edition (2011) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.Technology -
Technical committeeTypeAcronymIEC 61347-2-3CommitteePublished year2011KeywordsDescription
IEC 61347-2-3:2011+A1:2016 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating fromthe supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:
- rectifying test conditions when dimming;
- construction requirements;
- measurement circuits and limits for HF leakage currents;
- modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy. This consolidated version consists of the second edition (2011) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-2CommitteePublished year2011Description
IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV.
This publication is to be read in conjunction with IEC 61347-1:2007.
Technology -
Technical committeeTypeAcronymIEC 61347-2-14CommitteePublished year2018KeywordsDescription
IEC 61347-2-14:2018 specifies particular safety requirements for electronic controlgear for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating frequencies deviating from the supply frequency, associated with fluorescent induction lamps as specified in IEC 62532 and IEC 62639, for high-frequency operation.
Technology -
Technical committeeTypeAcronymIEC 61347-2-13CommitteePublished year2014KeywordsDescription
IEC 61347-2-13:2014+A1:2016 specifies particular safety requirements for electronic controlgear for use on d.c. or a.c. supplies up to 1 000 V (a.c. at 50 Hz or 60 Hz) and at an output frequency which can deviate from the supply frequency, associated with LED modules. Controlgear for LED modules specified in this standard are designed to provide constant voltage or current at SELV or higher voltages. Deviations from the pure voltage and current types do not exclude the gear from this standard. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) Replacement of the SELV-equivalent requirements by SELV requirements and reference to the SELV requirements of Annex L in IEC 61347-1:2007/AMD2:2012.
b) Reference to IEC 61347-1 for the protection against accidental contact with live parts, moisture resistance and insulation and electric strength.
c) New Annex J for emergency lighting requirements.This publication shall be read in conjunction with IEC 61347-1:2012. This consolidated version consists of the second edition (2014) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
Technology -
Technical committeeTypeAcronymIEC 61347-2-12CommitteePublished year2005KeywordsDescription
IEC 61347-2-12:2005+A1:2010 specifies particular general and safety requirements for d.c. or a.c. supplied electronic ballasts. The supply comprises a.c. voltages up to 1000 V at 50 Hz/60 Hz. The type of ballast is an convertor that may contain igniting and stabilising elements for operation of a discharge lamp at d.c. or at a frequency that can deviate from the supply frequency. The lamps associated with the ballast are specified in IEC 60188 (High pressure mercury vapour lamps), IEC 60192 (Low pressure sodium vapour lamps), IEC 60662 (High pressure sodium vapour lamps), IEC 61167 (Metal halide lamps) and else for general purpose lighting. Ballasts for fluorescent lamps and for lamps for special applications like for theatre and for vehicles are excluded. The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. A vertical line in the margin shows where the base publication has been modified by amendment 1. Additions and deletions are displayed in red, with deletions being struck through. This consolidated version consists of the first edition (2005) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication.
This publication is to be read in conjunction with IEC 61347-1:2000.
Technology