Fuel Cell Technologies
-
Technical committeeTypeAcronymIEC 62282-4-101CommitteePublished year2014Description
IEC 62282-4-101:2014 covers safety requirements for fuel cell power systems intended to be used in electrically powered industrial trucks. This standard is limited to electrically powered industrial trucks and is applicable to material-handling equipment, e.g. forklifts. It applies to gaseous hydrogen-fuelled fuel cell power systems and direct methanol fuel cell power systems for electrically powered industrial trucks.
-
Technical committeeTypeAcronymIEC 62282-3-400:2016CommitteePublished year2016Description
IEC 62282-3-400:2016 applies to small stationary fuel cell power systems serving as a heating appliance providing both electric power and useful heat with or without a supplementary heat generator providing peak load function. This standard applies to fuel cell power systems that are intended to be permanently connected to the electrical system of the customer (end user). Direct connection to the mains (parallel operation) is also within the scope of this standard. This standard is limited to gas and liquid fuelled fuel cell CHP appliances that have a heat input based on lower heating value of less than or equal to 70 kW. This standard specifies the requirements for construction, safety, installation, fitness for purpose, rational use of energy, marking, and performance measurement of these appliances. This standard also provides regional and country specific requirements to facilitate the worldwide application of this IEC standard.
Technology -
Technical committeeTypeAcronymIEC 62282-3-300:2012CommitteePublished year2012KeywordsDescription
IEC 62282-3-300:2012 provides minimum safety requirements for the installation of indoor and outdoor stationary fuel cell power systems in compliance with IEC 62282-3-100 and applies to the installation of the following systems: - intended for electrical connection to mains directly or with a readily accessible, manually operable switch or circuit-breaker; - intended for a stand-alone power distribution system; - intended to provide AC or DC power; - with or without the ability to recover useful heat.
Technology -
Technical committeeTypeAcronymIEC 62282-3-300CommitteePublished year2012KeywordsDescription
IEC 62282-3-300:2012 provides minimum safety requirements for the installation of indoor and outdoor stationary fuel cell power systems in compliance with IEC 62282-3-100 and applies to the installation of the following systems:
- intended for electrical connection to mains directly or with a readily accessible, manually operable switch or circuit-breaker;
- intended for a stand-alone power distribution system;
- intended to provide AC or DC power;
- with or without the ability to recover useful heat. -
Technical committeeTypeAcronymIEC 62282-3-201:2017CommitteePublished year2017Description
IEC 62282-3-201:2017 provides test methods for the electrical, thermal and environmental performance of small stationary fuel cell power systems that meet the following criteria: - rated electric power output of less than 10 kW; - grid-connected/independent operation or stand-alone operation with single-phase AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding 1 500 V; - maximum allowable working pressure of less than 0,1 MPa (gauge) for the fuel and oxidant passages; - gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.) or liquid fuel (kerosene, methanol, etc.); - air as oxidant. This document describes type tests and their test methods only. This document covers fuel cell power systems whose primary purpose is the production of electric power. This new edition includes the following significant technical changes with respect to the previous edition: revision of test set-up, revision of measurement instruments, introduction of ramp-up test, introduction of rated operation cycle efficiency, introduction of electromagnetic compatibility (EMC) test, revision of exhaust gas test, introduction of typical durations of operation cycles.
Technology -
Technical committeeTypeAcronymIEC 62282-3-201CommitteePublished year2013Description
IEC 62282-3-201 provides test methods for the electrical, thermal and environmental performance of small stationary fuel cell power systems that meet the following criteria:
- rated electric power output of less than 10 kW;
- grid-connected/independent operation or stand-alone operation with single-phase AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding 1 500 V;
- maximum allowable working pressure of less than 0,1 MPa (gauge) for the fuel and oxidant passages;
- gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.) or liquid fuel (kerosene, methanol, etc.);
- air as oxidant.
This document describes type tests and their test methods only. This document covers fuel cell power systems whose primary purpose is the production of electric power.
This new edition includes the following significant technical changes with respect to the previous edition: revision of test set-up, revision of measurement instruments, introduction of ramp-up test, introduction of rated operation cycle efficiency, introduction of electromagnetic compatibility (EMC) test, revision of exhaust gas test, introduction of typical durations of operation cycles. -
Technical committeeTypeAcronymIEC 62282-3-200:2015CommitteePublished year2015Description
IEC 62282-3-200:2015 covers operational and environmental aspects of the stationary fuel cell power systems performance. The test methods apply as follows: - power output under specified operating and transient conditions; - electrical and heat recovery efficiency under specified operating conditions; - environmental characteristics; - for example, exhaust gas emissions, noise, etc. under specified operating and transient conditions. This new edition includes the following significant technical changes with respect to the previous edition: a stabilization zone of +- 10 % for thermal output of 100 % response time is provided instead of the tests for thermal output of 90 % response time, while the tests for electric output of 90 % response time remain as an option; the calculations for the ramp rate in kW/s are deleted and only the calculations for the response time (s) remain.
Technology -
Technical committeeTypeAcronymIEC 62282-3-200CommitteePublished year2011Description
IEC 62282-3-200 covers operational and environmental aspects of the stationary fuel cell power systems performance. The test methods apply as follows:
- power output under specified operating and transient conditions;
- electrical and heat recovery efficiency under specified operating conditions;
- environmental characteristics;
- for example, exhaust gas emissions, noise, etc. under specified operating and transient conditions. This new edition includes the following significant technical changes with respect to the previous edition: a stabilization zone of +- 10 % for thermal output of 100 % response time is provided instead of the tests for thermal output of 90 % response time, while the tests for electric output of 90 % response time remain as an option; the calculations for the ramp rate in kW/s are deleted and only the calculations for the response time (s) remain. -
Technical committeeTypeAcronymIEC 62282-3-100:2019 RLVCommitteePublished year2019KeywordsDescription
IEC 62282-3-100:2019 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 62282-3-100:2019 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. This document is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous areas. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition: a) recognition that fuel carrying components qualified to leakage standards (soundness) need not be considered as potential flammable leak sources; b) new annex for small power systems; and c) clarifications for numerous requirements and tests.
Technology -
Technical committeeTypeAcronymIEC 62282-3-100CommitteePublished year2012Description
IEC 62282-3-100:2019 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 62282-3-100:2019 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. This document is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous areas. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a) recognition that fuel carrying components qualified to leakage standards (soundness) need not be considered as potential flammable leak sources;
b) new annex for small power systems; and
c) clarifications for numerous requirements and tests