Fuel Cell Technologies

Title
IEC_TC 105
  • English
    Technical committee
    Type
    Acronym
    IEC 62282-2-100:2020
    Committee
    Published year
    2020
    Keywords
    Description

    IEC 62282-2-100:2020 provides safety related requirements for construction, operation under normal and abnormal conditions and the testing of fuel cell modules. This document deals with conditions that can yield hazards to persons and cause damage outside the fuel cell modules. Protection against damage inside the fuel cell modules is not addressed in this document, provided it does not lead to hazards outside the module. These requirements can be superseded by other standards for equipment containing fuel cell modules as required for particular applications. This first edition cancels and replaces IEC 62282-2, published in 2012. This edition includes the following significant technical changes with respect to IEC 62282­2:2012: - update of definitions, in particular fuel cell module for normal operation; - leakage values under normal and abnormal operation have been addressed; - a delayed ignition test has been included; - protective measures to limit gas leakage have been included; - the requirements for insulation between live parts and SELV have been updated; - the general safety strategy has been modified to reflect the needs for different application standards; the modifications are in line with similar modifications made to IEC 62282­3-100; - the electrical components clause has been modified to reflect the needs for different application standards; the modifications are in line with similar modifications made to IEC 62282-3-100; - protective earthing as part of the module or bonding as a measure within the installation has been introduced; - a dielectric strength test has been completely updated by referring to IEC 62744-1 for voltages up to 1 000 V AC/1 500 V DC; - a new “pressure drop method” leakage test method has been included; - a new Annex addressing significant hazards, hazardous situations and events dealt with in this document, and linked to 4.1 (General safety strategy) has been added.

  • English
    Technical committee
    Type
    Acronym
    IEC 62282-2
    Committee
    Published year
    2012
    Description

    IEC 62282-2-100:2020 provides safety related requirements for construction, operation under normal and abnormal conditions and the testing of fuel cell modules. This document deals with conditions that can yield hazards to persons and cause damage outside the fuel cell modules. Protection against damage inside the fuel cell modules is not addressed in this document, provided it does not lead to hazards outside the module. These requirements can be superseded by other standards for equipment containing fuel cell modules as required for particular applications.
    This first edition cancels and replaces IEC 62282-2, published in 2012. This edition includes the following significant technical changes with respect to IEC 62282­2:2012:
    • update of definitions, in particular fuel cell module for normal operation;
    • leakage values under normal and abnormal operation have been addressed;
    • a delayed ignition test has been included;
    • protective measures to limit gas leakage have been included;
    • the requirements for insulation between live parts and SELV have been updated;
    • the general safety strategy has been modified to reflect the needs for different application standards; the modifications are in line with similar modifications made to IEC 62282­-3-­100;
    • the electrical components clause has been modified to reflect the needs for different application standards; the modifications are in line with similar modifications made to IEC 62282-3-100;
    • protective earthing as part of the module or bonding as a measure within the installation has been introduced;
    • a dielectric strength test has been completely updated by referring to IEC 62744-1 for voltages up to 1 000 V AC/1 500 V DC;
    • a new “pressure drop method” leakage test method has been included;
    • a new Annex addressing significant hazards, hazardous situations and events dealt with in this document, and linked to 4.1 (General safety strategy) has been added.

  • English
    Technical committee
    Type
    Acronym
    IEC 60475
    Committee
    Published year
    2011
    Description

    IEC 60475:2011 is applicable to the procedure to be used for insulating liquids in delivery containers and in electrical equipment such as power and instrument transformers, reactors, bushings, oil-filled cables, oil-filled tank-type capacitors, switchgear and load tap changers. The main changes with respect to the previous edition are as follows:
    - withdrawal of askarels;
    - addition of recommendations concerning general health, safety and environmental protection;
    - additional details regarding the sampling of oil from electrical equipment, using various types of sampling devices appropriate for the different types of oil tests to be performed in the laboratory.