Solar Power
Solar Power
-
Technical committeeTypeAcronymIEC 60891:2009CommitteePublished year2009Description
IEC 60891:2009 defines procedures to be followed for temperature and irradiance corrections to the measured I-V (current-voltage) characteristics of photovoltaic devices. It also defines the procedures used to determine factors relevant for these corrections. Requirements for I-V measurement of photovoltaic devices are laid down in IEC 60904-1. The main technical changes with regard the previous edition are as follows:
- extends edition 1 translation procedure to irradiance change during I-V measurement;
- adds 2 new translation procedures;
- revises procedure for determination of temperature coefficients to include PV modules;
- defines new procedure for determination of internal series resistance;
- defines new procedure for determination of curve correction factor. -
Technical committeeTypeAcronymIEC 60364-7-712:2017 RLVCommitteePublished year2017KeywordsDescription
IEC 60364-7-712:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60364-7-712:2017 applies to the electrical installation of PV systems intended to supply all or part of an installation. The equipment of a PV installation, like any other item of equipment, is dealt with only so far as its selection and application in the installation is concerned. This new edition includes significant revisions and extensions, taking into account experience gained in the construction and operation of PV installations, and developments made in technology, since the first edition of this standard was published.
Technology -
Technical committeeTypeAcronymIEC 60269-6:2010CommitteePublished year2010KeywordsDescription
IEC 60269-6:2010 gives supplementary requirement to those given in IEC 60269-1 for fuse-links for protecting photovoltaic (PV) strings and photovoltaic (PV) arrays in equipment for circuits of nominal voltages up to 1 500 V d.c. This publication is to be read in conjunction with IEC 60269-1:2006.
Technology -
Technical committeeTypeAcronymEN 61730Published year2018KeywordsDescription
This part of IEC 61730 specifies and describes the fundamental construction requirements for photovoltaic (PV) modules in order to provide safe electrical and mechanical operation. Specific topics are provided to assess the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. This part of IEC 61730 pertains to the particular requirements of construction. IEC 61730‑2 defines the requirements for testing.
This International Standard series lays down IEC requirements of terrestrial photovoltaic modules suitable for long-term operation in open-air climates. This standard is intended to apply to all terrestrial flat plate module materials such as crystalline silicon module types as well as thin-film modules.
PV modules covered by this standard are limited to a maximum DC system voltage of 1 500 V.
This International Standard defines the basic requirements for various applications of PV modules, but it cannot be considered to encompass all national or regional codes. Specific requirements, e.g. for building, marine and vehicle applications, are not covered.
This International Standard does not address specific requirements for products that combine a PV module with power conversion equipment, monitoring or control electronics, such as integrated inverters, converters or output disabling functions.
While parts of this standard may be applicable to flat plate PV modules with internally generated low level concentration below 3 times, it was not written specifically to address these concerns.
This International Standard is designed to coordinate with the test sequences in the IEC 61215 series, so that a single set of samples may be used to perform both the safety and qualification of a photovoltaic module design.
The object of this International Standard is to define the requirements for the construction of photovoltaic modules with respect to safety. These requirements are intended to minimize the misapplication and misuse of PV modules or the failure of their components which could result in fire, electric shock and personal injury.
Additional construction requirements outlined in relevant ISO standards, or the national or local codes which govern the installation and use of these PV modules in their intended locations, should be considered in addition to the requirements contained within this standard.