Technical committeeTypeAcronymIEC 62439-7CommitteePublished year2011KeywordsDescription
IEC 62439-7:2011 specifies a redundancy protocol that is based on a ring topology, in which the redundancy protocol is executed at the end nodes, as opposed to being built into the switches. Each node detects link failure and link establishment using media-sensing technologies, and shares the link information with the other nodes, to guarantee fast connectivity recovery times. The nodes have equal RRP network management functions.
This publication is to be read in conjunction with IEC 62439-1:2010. The contents of the corrigendum of May 2015 have been included in this copy.
-
Technical committeeTypeAcronymIEC 62439-6CommitteePublished year2010KeywordsDescription
IEC 62439-6:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a recovery protocol based on a ring topology, designed to react deterministically on a single failure of an inter-switch link or switch in the network. Each switch has equal management role in the network. Double rings are supported. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
- adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
- adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
- moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
- moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
- moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
- moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
- moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
- adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
- adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
- introducing the DRP protocol as IEC 62439-6.This publication is to be read in conjunction with IEC 62439-1:2010.
-
Technical committeeTypeAcronymIEC 62439-4CommitteePublished year2010KeywordsDescription
IEC 62439-4:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a redundancy protocol that is based on the duplication of the network, the redundancy protocol being executed within the end nodes, as opposed to a redundancy protocol built in the switches. The switchover decision is taken in each node individually. The cross-network connection capability enables single attached end nodes to be connected on either of the two networks. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
- adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
- adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
- moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
- moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
- moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
- moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
- moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
- adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
- adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
- introducing the DRP protocol as IEC 62439-6.This publication is to be read in conjunction with IEC 62439-1:2010.
-
Technical committeeTypeAcronymIEC 62439-3CommitteePublished year2012KeywordsDescription
IEC 62439-3:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 62439-3:2016 is applicable to high-availability automation networks based on the Ethernet technology. This part of IEC 62439 specifies two redundancy protocols designed to provide seamless recovery in case of single failure of an inter-bridge link or bridge in the network, which are based on the same scheme: parallel transmission of duplicated information. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous
edition:
- technical corrections and extension of specifications;
- consideration of IEC 61588 clock synchronization with end-to-end delay measurement alongside the existing peer-to-peer delay measurement in PRP. -
Technical committeeTypeAcronymIEC 62439-2CommitteePublished year2010KeywordsDescription
IEC 62439-2:2016 is applicable to high-availability automation networks based on the ISO/IEC/IEEE 8802-3 (IEEE 802.3) (Ethernet) technology. This part of the IEC 62439 series specifies a recovery protocol based on a ring topology, designed to react deterministically on a single failure of an inter-switch link or switch in the network, under the control of a dedicated media redundancy manager node.This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- adding a protocol extension to select the media redundancy manager automatically;
- adding a protocol to redundantly connect media redundancy protocol rings.This publication is to be read in conjunction with IEC 62439-1:2010.
-
Technical committeeTypeAcronymIEC 62264-4CommitteeKeywordsDescription
IEC 62264-4:2015 defines object models and attributes exchanged between Level 3 manufacturing operations management activities defined in IEC 62264-3.
-
Technical committeeTypeAcronymIEC 62264-2CommitteePublished year2013KeywordsDescription
IEC 62264-2:2013 specifies generic interface content exchanged between manufacturing control functions and other enterprise functions. The interface considered is between Level 3 manufacturing systems and Level 4 business systems in the hierarchical model defined in IEC 62264-1. The goal is to reduce the risk, cost, and errors associated with implementing the interface. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. It includes the following technical:
- addition of object models for exchange information used in manufacturing operations management activities;
- displacement of the UML object models that were in IEC 62264-1:2003 into this standard so that the object models and the associated attribute tables were available in the same document;
- addition of the Hierarchy scope object definition to replace the Location attribute used in the previous edition;
- addition of a value type section to define the exchange of non-simple value types;
- definition of simple value types were defined using the ISO 15000-5. -
Technical committeeTypeAcronymIEC 61987-15CommitteePublished year2016KeywordsDescription
IEC 61987-15:2016 provides operating list of properties (OLOP) for the description of the operating parameters and the collection of requirements for level measuring equipment, and device lists of properties (DLOPs) for the description of a range of level measuring equipment types.
-
Technical committeeTypeAcronymIEC 61784-1CommitteePublished year2014KeywordsDescription
IEC 61784-1:2019 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory manufacturing and process control. This fifth edition cancels and replaces the fourth edition published in 2014 it constitutes a technical revision. The main changes are:
• update of the dated references to the IEC 61158 series, to IEC 61784 2, to the IEC 61784 3 series, to the IEC 61784-5 series and to IEC 61918 throughout the document;
• update of selection tables CPF 2, CPF 4 and CPF 8