IEC

IEC

  • English
    Technical committee
    Type
    Acronym
    IEC TS 61400-25-71:2019
    Committee
    Published year
    2019
    Description

    IEC TS 61400-25-71:2019 focus on the communications between wind power plant components such as wind turbines and actors such as SCADA systems. Non­-IEC 61850/IEC 61400-25 internal communication within wind power plant components is outside the normative scope of the IEC 61400-25 series. This document describes how to extend the IEC 61400-25 series with the IEC 61850­6 Substation Configuration description Language (SCL) file format for describing communication­-related Intelligent Electronic Device (IED) configurations of a wind turbine, wind power plant controller, meteorological mast, etc. The extension of SCL to the wind domain is intended to simplify integration of wind power plant equipment for clients, as well as their integration to the electrical system. The adoption of SCL allows formalised tool-based exchange of IED parameters, communication system configurations, switch yard (function) structures, as well as description of the relations between them. The purpose of this format is to formally and efficiently exchange wind turbine and wind power plant IED capability descriptions, and system descriptions between IED engineering tools and the system engineering tool(s) of different manufacturers in a compatible way. The file format is also intended to provide report configuration and alarms as well as HMI interface information from a wind power plant. This information can be used to engineer overlying SCADA systems for the site, for connected DSO, or TSO, or for fleet operators' maintenance and surveillance systems. Finally, the SCL is intended as a documentation of the configuration and topology of the delivered system.

    Technology
  • English
    Technical committee
    Type
    Acronym
    IEC TS 61400-14:2005
    Committee
    Published year
    2005
    Description

    Gives guidelines for declaring the apparent sound power level and tonality of a batch of wind turbines. Is to be used in conjunction with IEC 61400-11 which gives measurement procedures for apparent sound power level and tonality. This publication is of high relevance for Smart Grid.

    Technology
  • English
    Technical committee
    Type
    Acronym
    IEC TS 60904-13:2018
    Committee
    Published year
    2018
    Description

    IEC TS 60904-13:2018(E) specifies methods to: - capture electroluminescence images of photovoltaic modules, - process images to obtain metrics about the images taken in quantitative terms, and - provide guidance to qualitatively interpret the images for features in the image that are observed. This document is applicable to PV modules measured with a power supply that places the cells in the modules in forward bias.

  • English
    Technical committee
    Type
    Acronym
    IEC TS 60904-1-2:2019
    Committee
    Published year
    2019
    Description

    IEC TS 60904-1-2:2019 describes procedures for the measurement of the current-voltage (I-V) characteristics of bifacial photovoltaic devices in natural or simulated sunlight. It is applicable to single PV cells, sub-assemblies of such cells or entire PV modules This document may be applicable to PV devices designed for use under concentrated irradiation if they are measured without the optics for concentration, and irradiated using direct normal irradiance and a mismatch correction with respect to a direct normal reference spectrum is performed. This document describes the additional requirements for the measurement of I-V characteristics of bifacial PV devices.

  • English
    Type
    Acronym
    IEC TS 60364-8-3
    Committee
    Published year
    2020
    Description

    IEC TS 60364-8-3:2020 (E) specifies requirements and recommendations for the safe and proper functioning of prosumers' electrical installations.
    It is intended for use by contractors, users, facility managers and similar of electrical low-voltage installations.
    This document also provides requirements and recommendations on technical parameters and their limiting values influencing:
    a) safety:
    – protection;
    – alarm;
    b) proper functioning:
    – stability (voltage, frequency, etc);
    – reliability (power quality, interoperability of communication, etc);
    – energy management (power, power factor, current, stored energy, etc);
    – ability to ensure correct operation of equipment.
    This document also provides requirements and recommendations on data exchange models, and test procedures for the prosumer’s electrical installations that could include the following applications:
    – local generating sources (e.g. photovoltaic systems, rotating generators, wind turbines);
    – energy storage units (e.g. stationary secondary batteries);
    – electric vehicle charging and/or discharging;
    – prosumer’s energy measurement unit (PEMU);
    – control and monitoring system;
    – loads which can be controlled.
    This part of IEC 60364 is intended to be applied in conjunction with the other parts of IEC 60364.

  • English
    Type
    Acronym
    IEC TS 60079-46
    Committee
    Published year
    2017
    Description

    IEC TS 60079-46:2017 specifies requirements for the design, construction, assembly, testing, inspection, marking, documenting and assessment of equipment assemblies for use in explosive atmospheres under the responsibility of the manufacturer of the equipment assembly. The requirements of this document apply to individual items according to the IEC 60079 series or ISO 80079 series that comprise the assembly and that have individual certificates. These individual items are then integrated as part of the equipment assembly. Also included are requirements to address aspects for the assembly which may be beyond the certificates of the individual items forming the assembly. The scope of this document includes assessment of the additional requirements for assemblies for hazardous areas and does not include requirements for non-hazardous areas. It is assumed that compliance with other electrical or mechanical requirements that are applicable for non-hazardous areas will be verified by either the same or different party in addition to the requirements of this document. This document does not apply to:
    - equipment which is covered, in its entirety, by one or more IEC 60079 and ISO 80079 equipment types of protection;
    - pressurized rooms, “p”, in accordance with IEC 60079-13, artificial ventilation for the protection of analyzer(s) houses in accordance with IEC TR 60079-16, and other standards addressing specific Ex assemblies;
    - installation at the end-user site under the scope of IEC 60079-14;
    - classification of the hazardous area;
    - equipment assemblies for mines susceptible to firedamp (Group I applications);
    - inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
    - rooms used for medical purposes;
    - electrical installations in areas where the hazard is due to flammable mist.
    The specification is only intended to provide validation for the initial supply of an assembly.

  • English
    Type
    Acronym
    IEC TS 60079-43
    Committee
    Published year
    2017
    Description

    IEC TS 60079-43:2017(E) which is a Technical Specification, provides guidance for equipment for use in explosive atmospheres in environments which may include ambient temperatures below -20 °С, and additional adverse conditions, including maritime applications. The purpose of this document is to provide recommendations to be considered for the design, manufacture and use of equipment. It is intended that this document be used for equipment operating within the environmental range specified on the certificate for the equipment. This document is intended to be used in conjunction with the IEC 60079 series and the ISO/IEC 80079 series.

  • English
    Type
    Acronym
    IEC TS 60079-32-1:2013+AMD1:2017
    Committee
    Published year
    2017
    Description

    IEC TS 60079-32-1:2013+A1:2017 gives guidance about the equipment, product and process properties necessary to avoid ignition and electrostatic shock hazards arising from static electricity as well as the operational requirements needed to ensure safe use of the equipment, product or process. It can be used in a risk assessment of electrostatic hazards or for the preparation of product family or dedicated product standards for electrical or non-electrical machines or equipment. The purpose of this document is to provide standard recommendations for the control of static electricity, such as earthing of conductors, reduction of charging and restriction of chargeable areas of insulators. In some cases static electricity plays an integral part of a process, e.g. electrostatic coating, but often it is an unwelcome side effect and it is with the latter that this guidance is concerned. If the standard recommendations given in this document are fulfilled it can be expected that the risk of hazardous electrostatic discharges in an explosive atmosphere is at an acceptably low level. This consolidated version of the official IEC Standard and its amendment consists of the first edition (2013) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.

  • English
    Technical committee
    Type
    Acronym
    IEC TS 60076-23:2018
    Committee
    Published year
    2018
    Keywords
    Description

    IEC TS 60076-23:2018(E) specifies requirements for devices for the suppression of DC magnetic bias of power transformers and convertor transformers. It includes requirements for service conditions, structures, testing, packing, transport and storage.
    The devices are connected to neutral points of power transformers and converter transformers to suppress DC bias current in the case an HVDC system is operated in monopole ground return mode or bipolar unbalanced mode. In the case of dedicated metallic return HVDC system, the devices are useful to mitigate DC stray current flowing through power transformers and converter transformers during transient conditions such as DC line fault.
    This document applies to DC magnetic bias suppression devices for operation at frequencies of 50 Hz and 60 Hz on power systems having voltages above 110 kV.
    Show less

    Technology
  • English
    Technical committee
    Type
    Acronym
    IEC TS 60076-23
    Committee
    Published year
    2018
    Description

    IEC TS 60076-23:2018(E) specifies requirements for devices for the suppression of DC magnetic bias of power transformers and convertor transformers. It includes requirements for service conditions, structures, testing, packing, transport and storage.
    The devices are connected to neutral points of power transformers and converter transformers to suppress DC bias current in the case an HVDC system is operated in monopole ground return mode or bipolar unbalanced mode. In the case of dedicated metallic return HVDC system, the devices are useful to mitigate DC stray current flowing through power transformers and converter transformers during transient conditions such as DC line fault.
    This document applies to DC magnetic bias suppression devices for operation at frequencies of 50 Hz and 60 Hz on power systems having voltages above 110 kV.