Stationary Lead-Acid Batteries
Stationary Lead-Acid Batteries
-
Technical committeeTypeAcronymIEC 60896-22:2004CommitteePublished year2004Description
This part of IEC 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications. The objective of this part of IEC 60896 is to assist the specifier in the understanding of the purpose of each test contained within IEC 60896-21 and provide guidance on a suitable requirement that will result in the battery meeting the needs of a particular industry application and operational condition. This standard is used in conjunction with the common test methods described in IEC 60896-21 and is associated with all types and construction of valve regulated stationary lead-acid cells and monoblocs used in standby power applications.
Technology -
Technical committeeTypeAcronymIEC 60896-21:2004CommitteePublished year2004Description
This part of IEC 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications. The objective of this part of IEC 60896 is to specify the methods of test for all types and construction of valve regulated stationary lead acid cells and monobloc batteries used in standby power applications.
Technology -
Technical committeeTypeAcronymIEC 60896-11:2002CommitteePublished year2002Description
This part of IEC 60896 is applicable to lead-acid cells and batteries which are designed for service in fixed locations (i.e. not habitually to be moved from place to place) and which are permanently connected to the load and to the d.c. power supply. Batteries operating in such applications are called "stationary batteries". Any type or construction of lead-acid battery may be used for stationary battery applications. This part 11 of the standard is applicable to vented types only. This first edition of IEC 60896-11 cancels and replaces IEC 60896-1 (first edition) published in 1987 and its amendments 1 (1988) and 2 (1990), and constitutes a technical revision.
Technology