Smart City
Smart City
-
Technical committeeTypeAcronymIEC 61000-4-20CommitteePublished year2010KeywordsDescription
IEC 61000-4-20:2010 relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. These types include open structures (for example, striplines and electromagnetic pulse simulators) and closed structures (for example, TEM cells). These structures can be further classified as one-, two-, or multi-port TEM waveguides. The frequency range depends on the specific testing requirements and the specific TEM waveguide type. The object of this standard is to describe:
- TEM waveguide characteristics, including typical frequency ranges and EUT-size limitations;
- TEM waveguide validation methods for EMC tests;
- the EUT (i.e. EUT cabinet and cabling) definition;
- test set-ups, procedures, and requirements for radiated emission testing in TEM waveguides and
- test set-ups, procedures, and requirements for radiated immunity testing in TEM waveguides.
IEC 61000-4-20:2010 does not intend to specify the tests to be applied to any particular apparatus or system(s). The main intention of this standard is to provide a general basic reference for all interested product committees of the IEC. For radiated emissions testing, product committees should select emission limits and test methods in consultation with CISPR standards. For radiated immunity testing, product committees remain responsible for the appropriate choice of immunity tests and immunity test limits to be applied to equipment within their scope. This standard describes test methods that are separate from those of IEC 61000-4-3. This second edition cancels and replaces the first edition published in 2003 and its amendment 1 (2006), and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendment are the following:
- consistency of terms (e.g. test, measurement, etc.) has been improved;
- clauses covering test considerations, evaluations and the test report have been added;
- references to large TEM waveguides have been eliminated;
- a new informative annex has been added to deal with calibration of E-field probes. -
Technical committeeTypeAcronymIEC 61000-4-2CommitteePublished year2008Description
IEC 61000-4-2:2008 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and from personnel to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures. The object of IEC 61000-4-2:2008 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur frompersonnel to objects near vital equipment. IEC 61000-4-2:2008 defines typical waveform of the discharge current, range of test levels, test equipment, test setup, test procedure, calibration procedure and measurement uncertainty. IEC 61000-4-2:2008 gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation. This second edition cancels and replaces the first edition published in 1995, its amendment 1 (1998) and its amendment 2 (2000) and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendments are the following:
- the specifications of the target have been extended up to 4 GHz. An example of target matching these requirements is also provided;
- information on radiated fields from human-metal discharge and from ESD generators is provided;
- measurement uncertainty considerations with examples of uncertainty budgets are given too. -
Technical committeeTypeAcronymIEC 61000-4-19CommitteePublished year2014KeywordsDescription
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines:
- test waveforms;
- range of test levels;
- test equipment;
- test setup;
- test procedures;
- and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC -
Technical committeeTypeAcronymIEC 61000-4-17CommitteePublished year1999KeywordsDescription
Defines test methods for immunity to ripple at the d.c. input power port of electrical or electronic equipment. Applies to low-voltage d.c. power ports of equipment supplied by external rectifier systems, or batteries which are being charged. This standard defines
- test voltage waveform;
- range of test levels;
- test generator;
- test set-up;
- test procedure.
This consolidated version consists of the first edition (1999), its amendment 1 (2001) and its amendment 2 (2008). Therefore, no need to order amendments in addition to this publication. -
Technical committeeTypeAcronymIEC 61000-4-16CommitteePublished year1998KeywordsDescription
IEC 61000-4-16:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61000-4-16:2015 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. It has the status of a basic EMC publication in accordance with IEC Guide 107. This second edition cancels and replaces the first edition published in 1998, Amendment 1:2001 and Amendment 2:2009. This edition constitutes a technical revision. -
Technical committeeTypeAcronymIEC 61000-4-14CommitteePublished year1999KeywordsDescription
Applies to electrical and/or electronic equipment that have a rated input current up to 16 A per phase. Aims to establish a reference for evaluating the immunity of electric and/or electronic equipment when subjected to positive and negative low amplitude voltage fluctuations. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial power supply networks. Has the status of a Basic EMC publication.
-
Technical committeeTypeAcronymIEC 61000-4-13CommitteePublished year2002KeywordsDescription
IEC 61000-4-13:2002+A1:2009+A2:2015 defines the immunity test methods and range of recommended basic test levels for electrical and electronic equipment with rated current up to 16 A per phase at disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz mains) for harmonics and interharmonics on low voltage power networks. It establishes a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to harmonics and inter-harmonics and mains signalling frequencies. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This consolidated version consists of the first edition (2002), its amendment 1 (2009) and its amendment 2 (2015). Therefore, no need to order amendments in addition to this publication.
-
Technical committeeTypeAcronymIEC 61000-4-12CommitteePublished year2006KeywordsDescription
IEC 61000-4-12:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
It has the status of a basic EMC publication in accordance with IEC Guide 107.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a mathematical modelling of ring wave waveform;
b) new Annex B on selection of generators and test levels;
c) new Annex C on explanatory notes;
d) new Annex D on measurement uncertainty;
e) addition of high speed CDN;
f) addition of a calibration procedure for CDN. -
Technical committeeTypeAcronymIEC 61000-4-10CommitteePublished year1993KeywordsDescription
IEC 61000-4-10:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61000-4-10:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to damped oscillatory magnetic disturbances related to medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision. -
Technical committeeTypeAcronymIEC 61000-4-1CommitteePublished year2006KeywordsDescription
IEC TR 61000-4-1:2016(E) gives information and guidance on the EMC basic standards and other basic EMC documents published in the IEC 61000-4 series. Those basic standards describe mainly immunity tests to be considered and applied for electric and electronic equipment, including systems. It has the status of a basic EMC publication in accordance with IEC Guide 107. This first edition as a Technical Report cancels and replaces the third edition of the International Standard published in 2006. This edition constitutes a technical revision.