Lighting

Lighting

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-22
    Committee
    Published year
    2014
    Description

    IEC 60598-2-22:2014+A1:2017 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition published in 1997, AMD1:2002 and AMD2:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    a) Clause 22.3, addition of definitions for PELF and Self-contained portable emergency luminaire;
    b) Clause 22.5, updated with the introduction of requirements for non-replaceable lamp and batteries;
    c) Clause 22.6, improved requirements to confirm that the charge indication is correctly connected to the circuit together with other clarifications regarding the controlgear and the remote box with its connecting cabe to the emergency luminaire;
    d) Clause 22.12, improved requirements to ensure that the luminaire shall not become unsafe;
    e) Clause 22.16, full revision of the photometric testing to align with ISO and CIE;
    f) Clause 22.17, now only references the requirements which are now covered in IEC 61347 2-7;
    g) Clause 22.19, now only references the requirements which are now covered in IEC 61347 2-7;
    h) Annex A, now includes nickel metal hydride batteries and reference to cell types in IEC 61951-1;
    i) Annex B, minor changes to the classifications;
    j) Annex C, Figure C.1 deleted in favour of a revised text;
    k) Annex E, the additional requirements covering self-contained portable emergency luminaires. This publication is to be read in conjunction with IEC 60598-1:2014. The contents of the corrigenda of March 2015 and April 2016 have been included in this copy. This consolidated version consists of the fourth edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-21
    Committee
    Published year
    2014
    Description

    IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V.
    The contents of the corrigendum of December 2016 have been included in this copy.
    This publication is to be read in conjunction with IEC 60598-1:2014.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-20
    Committee
    Published year
    2014
    Description

    IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC 60598-2-21. This fourth edition cancels and replaces the third edition (2010). This edition includes the following significant technical changes with respect to the previous edition, where the requirements for rope lights (sealed lighting chains) have been removed and are now dealt with in IEC 60598-2-21. The contents of the corrigendum of December 2016 have been included in this copy.

    This publication is to be read in conjunction with IEC 60598-1:2014

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-2
    Committee
    Published year
    2011
    Description

    IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-14
    Committee
    Published year
    2009
    Description

    IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard.

    This publication is intended to be read in conjunction with IEC 60598-1:2008.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-1
    Committee
    Published year
    2020
    Description

    IEC 60598-1:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
    IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
    - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
    - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
    - Addition of Subclause 3.3.25, UV protection of cable;
    - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
    - Revision of the requirements for functional earth and protective earth;
    - Addition of Clause 4.35, Protection against fast rotating parts;
    - Revision of Clause 3.2, Rated voltage marking;
    - Revision of Subclause 5.2.10, Cord anchorage;
    - Revision of Annex G for touch current and protective conductor current test set-up;
    - Addition of requirements for constant light output function and programmable current output;
    - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
    - Introduction of PELV;
    - Introduction of Ethernet power supply connection for luminaires (PoE);
    - Section 9, Introduction of IPX9;
    - Addition of Subclause 3.3.26 for wall mounted luminaires;
    - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
    - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
    - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
    - Revision of Subclause 10.2.2, alternative DC electric strength test;
    - Revision of Annex D for recessed luminaires;
    - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
    - Revision of use of bridging capacitors in luminaires;
    - Revision of electrical connection to class III plugs.

  • English
    Technical committee
    Type
    Acronym
    IEC 60432-3
    Committee
    Published year
    2012
    Description

    IEC 60432-3:2012 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications:
    - projection (including cinematograph and still projection),
    - photographic (including studio),
    - floodlighting,
    - special purpose,
    - general purpose,
    - stage lighting.
    This second edition of IEC 60432-3 cancels and replaces the first edition published in 2002, Amendment 1 (2005) and Amendment 2 (2008). The main changes with respect to the previous edition are as follows:
    - adapting the cold fill pressure requirements and tests for self-shielded lamps to the state of the technology,
    - introduction of requirements to fully cover photobiological safety according to IEC 62471.

  • English
    Technical committee
    Type
    Acronym
    IEC 60432-2
    Committee
    Published year
    1999
    Keywords
    Description

    IEC 60432-2:1999+A1:2005+A2:2012 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics:
    - rated wattage up to and including 250 W;
    - rated voltage of 50 V to 250 V inclusive;
    - caps B15d, B22d, E12, E14, E17, E26, E26d, E26/50x39, E27 or E27/51x39.
    This standard shall be used in conjunction with IEC 60432-1. This consolidated version consists of the second edition (1999), its amendment 1 (2005) and its amendment 2 (2012). Therefore, no need to order amendments in addition to this publication.

    This publication is to be read in conjunction with IEC 60432-1:1999.

  • English
    Technical committee
    Type
    Acronym
    IEC 60432-1
    Committee
    Published year
    1999
    Keywords
    Description

    IEC 60432-1:1999+A1:2005+A2:2011 specifies the safety and interchangeability requirements of tungsten filament incandescent lamps for general lighting service having:
    - rated wattage up to and including 200 W;
    - rated voltage of 50 V to 250 V inclusive;
    - bulbs of the A, B, C, G, M, P, PS, PAR or R shapes* , or other bulb shapes where the lamps are intended to serve the same purpose as lamps with the foregoing bulb shapes;
    - bulbs with all kinds of finishes;
    - caps B15d, B22d, E12, E14, E17, E26** , E26d, E26/50x39, E27 or E27/51x39. The technical content is therefore identical to the base edition and its amendments and has been prepared for user convenience. It bears the edition number 2.2. A vertical line in the margin shows where the base publication has been modified by amendments 1 and 2. This consolidated version consists of the second edition (1999), its amendment 1 (2005) and its amendment 2 (2011). Therefore, no need to order amendments in addition to this publication.

  • English
    Technical committee
    Type
    Acronym
    IEC 60357
    Committee
    Published year
    2002
    Keywords
    Description

    This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000