Cyber Security
Cyber Security
-
Technical committeeTypeAcronymIEC 62056-5-3CommitteePublished year2015KeywordsDescription
IEC 62056-5-3:2017 specifies the DLMS/COSEM application layer in terms of structure, services and protocols for DLMS/COSEM clients and servers, and defines rules to specify the DLMS/COSEM communication profiles. It defines services for establishing and releasing application associations, and data communication services for accessing the methods and attributes of COSEM interface objects, defined in IEC 62056-6-2 using either logical name (LN) or short name (SN) referencing. This third edition cancels and replaces the second edition of IEC 62056-5-3, published in 2016. It constitutes a technical revision. The significant technical changes with respect to the previous edition are listed in Annex K (Informative).
-
Technical committeeTypeAcronymIEC 62056-46CommitteePublished year2002KeywordsDescription
Specifies the data link layer for connection-oriented, HDLC-based, asynchronous communication profile. This consolidated version consists of the first edition (2002) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication.
This publication is of high relevance for Smart Grid.
-
Technical committeeTypeAcronymIEC 62056-3-1:2013CommitteePublished year2013Description
IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported: - base profile; - profile with DLMS; - profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are: - addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model, - review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media; - ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.
Technology -
Technical committeeTypeAcronymIEC 62056-3-1CommitteePublished year2013KeywordsDescription
IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported:
- base profile;
- profile with DLMS;
- profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are:
- addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model,
- review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media;
- ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds. -
Technical committeeTypeAcronymIEC 62056-21:2002CommitteePublished year2002Description
Describes hardware and protocol specifications for local meter data exchange. In such systems, a hand-held unit (HHU) or a unit with equivalent functions is connected to a tariff device or a group of devices. This publication is of high relevance for Smart Grid.
Technology -
Technical committeeTypeAcronymIEC 62056-21CommitteePublished year2002KeywordsDescription
Describes hardware and protocol specifications for local meter data exchange. In such systems, a hand-held unit (HHU) or a unit with equivalent functions is connected to a tariff device or a group of devices.
This publication is of high relevance for Smart Grid.
-
Technical committeeTypeAcronymIEC 62056-1-0:2014CommitteePublished year2014Description
IEC 62056-1-0:2014 provides information on the smart metering use cases and on architectures supported by the IEC 62056 DLMS/COSEM series of standards specifying electricity meter data exchange. It describes the standardization framework including: - the principles on which the standards shall be developed; - the ways the existing standards shall be extended to support new use cases and to accommodate new communication technologies, while maintaining coherency; - the aspects of interoperability and information security. It also provides guidance for selecting the suitable standards for a specific interface within the smart metering system.
Technology -
Technical committeeTypeAcronymIEC 62056-1-0CommitteePublished year2014KeywordsDescription
IEC 62056-1-0:2014 provides information on the smart metering use cases and on architectures supported by the IEC 62056 DLMS/COSEM series of standards specifying electricity meter data exchange. It describes the standardization framework including:
- the principles on which the standards shall be developed;
- the ways the existing standards shall be extended to support new use cases and to accommodate new communication technologies, while maintaining coherency;
- the aspects of interoperability and information security. It also provides guidance for selecting the suitable standards for a specific interface within the smart metering system. -
Technical committeeTypeAcronymIEC 61970-555CommitteePublished year2013Description
IEC TS 61970-555:2016(E) specifies a Component Interface Specification (CIS) for Energy Management Systems Application Program Interfaces (EMS-API). This part specifies the format and rules for exchanging modelling information based upon the CIM. It uses the CIM/E Schema as the meta-model framework for constructing CIM/E documents of power system modelling information. The style of these documents is called CIM/E format. CIM/E is suitable for use in online model exchange of power system applications.
Technology -
Technical committeeTypeAcronymIEC 61970-552CommitteePublished year2013Description
IEC 61970-552:2016 specifies the format and rules for exchanging modelling information based upon the CIM. It uses the CIM RDF Schema presented in IEC 61970-501 as the meta-model framework for constructing XML documents of power system modelling information. The style of these documents is called CIMXML format. This new edition includes the following significant technical changes with respect to the previous edition:
- new clause that defines the versioning of CIMXML format;
- addition of a statement about mandatory header;