Luminaires

Title
IEC_TC 34_SC 34D
  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-2
    Committee
    Published year
    2011
    Description

    IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-17
    Committee
    Published year
    2017
    Description

    IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V.
    This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision.
    This edition includes the following significant technical changes with respect to the previous edition:
    a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1.
    b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-14
    Committee
    Published year
    2009
    Description

    IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard.

    This publication is intended to be read in conjunction with IEC 60598-1:2008.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-1
    Committee
    Published year
    2020
    Description

    IEC 60598-1:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
    IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
    - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
    - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
    - Addition of Subclause 3.3.25, UV protection of cable;
    - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
    - Revision of the requirements for functional earth and protective earth;
    - Addition of Clause 4.35, Protection against fast rotating parts;
    - Revision of Clause 3.2, Rated voltage marking;
    - Revision of Subclause 5.2.10, Cord anchorage;
    - Revision of Annex G for touch current and protective conductor current test set-up;
    - Addition of requirements for constant light output function and programmable current output;
    - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
    - Introduction of PELV;
    - Introduction of Ethernet power supply connection for luminaires (PoE);
    - Section 9, Introduction of IPX9;
    - Addition of Subclause 3.3.26 for wall mounted luminaires;
    - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
    - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
    - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
    - Revision of Subclause 10.2.2, alternative DC electric strength test;
    - Revision of Annex D for recessed luminaires;
    - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
    - Revision of use of bridging capacitors in luminaires;
    - Revision of electrical connection to class III plugs.