Smart City
Smart City
-
Technical committeeTypeAcronymIEC TS 62257-7-1:2010CommitteePublished year2010KeywordsDescription
IEC/TS 62257-7-1:2010(E) specifies the general requirements for the design and the safety of generators used in decentralized rural electrification systems. Provides requirements for ELV and LV PV arrays. Particular attention must be paid to voltage level, as this is important for safety reasons and has an influence on protective measures and on the skill and ability level of operators. The main technical changes with regard to the previous edition are the following: - this new version is focused on small PV generators up to 100 kWp; - it provides case studies.
-
Technical committeeTypeAcronymIEC TS 62056-52:1998CommitteePublished year1998Description
Provides all the information specific to the management DLMS server of the protocols described in IEC 62056-31, 62056-41 and 62056-51. This publication is a Technical Report type 2.
Technology -
Technical committeeTypeAcronymIEC TS 62056-51:1998CommitteePublished year1998Description
Describes an architectured application layer used for communication with metering equipment. The associated physical medium and lower layer protocols in a collapsed three-layer model are unspecified. The DLMS protocol is covered by IEC 61334-4-41. This is a Technical Report type 2.
Technology -
Technical committeeTypeAcronymIEC TS 61970-556CommitteePublished year2013Description
IEC TS 61970-556:2016(E) specifies a CIM-based graphic exchange format (CIM/G). It includes graphic file structure and graphic element definitions. This document supports a mechanism for off-line exchange of graphic displays and on-line remote browsing of diagrams among distinct SCADA/EMS systems that may be provided by multiple vendors and located in different places.
-
Technical committeeTypeAcronymIEC TS 61970-555CommitteePublished year2013Description
IEC TS 61970-555:2016(E) specifies a Component Interface Specification (CIS) for Energy Management Systems Application Program Interfaces (EMS-API). This part specifies the format and rules for exchanging modelling information based upon the CIM. It uses the CIM/E Schema as the meta-model framework for constructing CIM/E documents of power system modelling information. The style of these documents is called CIM/E format. CIM/E is suitable for use in online model exchange of power system applications.
-
Technical committeeTypeAcronymIEC TR 62357-200:2015CommitteePublished year2015KeywordsDescription
IEC TR 62357-200:2015(E) applies to information exchange in power systems including, but not restricted to, substations, control centre, maintenance centre, energy management systems, synchrophasor-based grid stability systems, bulk energy generation, distributed energy generation (renewables), energy storage, load management. It addresses the issues encountered when migrating from Internet Protocol version 4 (IPv4) to Internet Protocol version 6 (IPv6). It describes migration strategies, covering impact on applications, communication stack, network nodes, configuration, address allocation, cyber security and the related management. This Technical Report considers backward compatibility and show concepts as well as necessary migration paths to IPv6 from IPv4 where necessary, for a number of protocols in the IEC 61850 framework.
Technology -
Technical committeeTypeAcronymIEC TR 62351-12:2016CommitteePublished year2016KeywordsDescription
IEC TR 62351-12:2016(E) discusses cyber security recommendations and engineering/operational strategies for improving the resilience of power systems with interconnected Distributed Energy Resources (DER) systems. It covers the resilience requirements for the many different stakeholders of these dispersed cyber-physical generation and storage devices, with the goal of enhancing the safety, reliability, power quality, and other operational aspects of power systems, particularly those with high penetrations of DER systems. It addresses the resilience issues for cyber-physical DER systems interconnected with the power grid, building on the concepts and the hierarchical architecture described in the Smart Grid Interoperability Panel (SGIP) draft DRGS Subgroup B White Paper - Categorizing Use Cases in Hierarchical DER Systems.
Technology -
Technical committeeTypeAcronymIEC TR 61850-7-510:2012CommitteePublished year2012KeywordsDescription
EC/TR 61850-7-510:2012(E) provides explanations on how to use the Logical Nodes defined in IEC 61850-7-410 as well as other documents in the IEC 61850 series to model complex control functions in power plants, including variable speed pumped storage power plants. This publication is to be used in conjunction with IEC 61850-7-410 which introduced the general modelling concepts of IEC 61850 to hydroelectric power plants. Keywords: power utility, automation, communication, hydroelectric
Technology -
Technical committeeTypeAcronymIEC TR 61850-7-510CommitteePublished year2012KeywordsDescription
IEC/TR 61850-7-510:2012(E) provides explanations on how to use the Logical Nodes defined in IEC 61850-7-410 as well as other documents in the IEC 61850 series to model complex control functions in power plants, including variable speed pumped storage power plants. This publication is to be used in conjunction with IEC 61850-7-410 which introduced the general modelling concepts of IEC 61850 to hydroelectric power plants. Keywords: power utility, automation, communication, hydroelectric
Technology -
Technical committeeTypeAcronymIEC TR 61366-7CommitteePublished year1998KeywordsDescriptionTechnology