Rural Electrification

Rural Electrification

  • English
    Technical committee
    Type
    Acronym
    IEC 60904-2
    Committee
    Published year
    2007
    Description

    IEC 60904-2:2015 is available as IEC 60904-2:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

    IEC 60904-2:2015 gives requirements for the classification, selection, packaging, marking, calibration and care of photovoltaic reference devices. This standard covers photovoltaic reference devices used to determine the electrical performance of photovoltaic cells, modules and arrays under natural and simulated sunlight. The main technical changes with regard to the previous edition are as follows:
    - addition of a test procedure in simulated sunlight of subsequent measurement of primary and secondary reference device;
    - definition of standard test conditions;
    - reduction of allowed diffuse component for secondary reference cell calibration.

  • English
    Technical committee
    Type
    Acronym
    IEC 60904-1
    Committee
    Published year
    2006
    Description

    IEC 60904-1:2020 describes procedures for the measurement of current-voltage characteristics (I-V curves) of photovoltaic (PV) devices in natural or simulated sunlight. These procedures are applicable to a single PV solar cell, a sub-assembly of PV solar cells, or a PV module. This document is applicable to non-concentrating PV devices for use in terrestrial environments, with reference to (usually but not exclusively) the global reference spectral irradiance AM1.5 defined in IEC 60904-3.
    This third edition cancels and replaces the second edition published in 2006. The main changes with respect to the previous edition are as follows:
    - Updated scope to include all conditions.
    - Added terms and definitions.
    - Reorganised document to avoid unnecessary duplication.
    - Added data analysis clause.
    - Added informative annexes (area measurement, PV devices with capacitance, dark I-V curves and effect of spatial non-uniformity of irradiance).

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-5
    Committee
    Published year
    2015
    Description

    IEC 60598-2-5:2015 specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. This third edition cancels and replaces the second edition published in 1998, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: it introduces requirements for the glass breaking test.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-3
    Committee
    Published year
    2002
    Description

    IEC 60598-2-3:2002+A1:2011 specifies requirements for:
    - luminaires for road, street lighting and other public outdoor lighting applications;
    - tunnel lighting;
    - column-integrated luminaires with a minimum total height above normal ground level of 2,5 m;
    - and for use with electrical lighting sources on supply voltages not exceeding 1 000 V.

    This publication is to be read in conjunction with IEC 60598-1:2008.

    This consolidated version consists of the third edition (2002) and its amendment 1 (2011) and has been prepared for user convenience. Therefore, no need to order amendment in addition to this publication.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-22
    Committee
    Published year
    2014
    Description

    IEC 60598-2-22:2014+A1:2017 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition published in 1997, AMD1:2002 and AMD2:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    a) Clause 22.3, addition of definitions for PELF and Self-contained portable emergency luminaire;
    b) Clause 22.5, updated with the introduction of requirements for non-replaceable lamp and batteries;
    c) Clause 22.6, improved requirements to confirm that the charge indication is correctly connected to the circuit together with other clarifications regarding the controlgear and the remote box with its connecting cabe to the emergency luminaire;
    d) Clause 22.12, improved requirements to ensure that the luminaire shall not become unsafe;
    e) Clause 22.16, full revision of the photometric testing to align with ISO and CIE;
    f) Clause 22.17, now only references the requirements which are now covered in IEC 61347 2-7;
    g) Clause 22.19, now only references the requirements which are now covered in IEC 61347 2-7;
    h) Annex A, now includes nickel metal hydride batteries and reference to cell types in IEC 61951-1;
    i) Annex B, minor changes to the classifications;
    j) Annex C, Figure C.1 deleted in favour of a revised text;
    k) Annex E, the additional requirements covering self-contained portable emergency luminaires. This publication is to be read in conjunction with IEC 60598-1:2014. The contents of the corrigenda of March 2015 and April 2016 have been included in this copy. This consolidated version consists of the fourth edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-21
    Committee
    Published year
    2014
    Description

    IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V.
    The contents of the corrigendum of December 2016 have been included in this copy.
    This publication is to be read in conjunction with IEC 60598-1:2014.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-20
    Committee
    Published year
    2014
    Description

    IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC 60598-2-21. This fourth edition cancels and replaces the third edition (2010). This edition includes the following significant technical changes with respect to the previous edition, where the requirements for rope lights (sealed lighting chains) have been removed and are now dealt with in IEC 60598-2-21. The contents of the corrigendum of December 2016 have been included in this copy.

    This publication is to be read in conjunction with IEC 60598-1:2014

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-2
    Committee
    Published year
    2011
    Description

    IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-2-14
    Committee
    Published year
    2009
    Description

    IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard.

    This publication is intended to be read in conjunction with IEC 60598-1:2008.

  • English
    Technical committee
    Type
    Acronym
    IEC 60598-1
    Committee
    Published year
    2020
    Description

    IEC 60598-1:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
    IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
    - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
    - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
    - Addition of Subclause 3.3.25, UV protection of cable;
    - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
    - Revision of the requirements for functional earth and protective earth;
    - Addition of Clause 4.35, Protection against fast rotating parts;
    - Revision of Clause 3.2, Rated voltage marking;
    - Revision of Subclause 5.2.10, Cord anchorage;
    - Revision of Annex G for touch current and protective conductor current test set-up;
    - Addition of requirements for constant light output function and programmable current output;
    - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
    - Introduction of PELV;
    - Introduction of Ethernet power supply connection for luminaires (PoE);
    - Section 9, Introduction of IPX9;
    - Addition of Subclause 3.3.26 for wall mounted luminaires;
    - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
    - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
    - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
    - Revision of Subclause 10.2.2, alternative DC electric strength test;
    - Revision of Annex D for recessed luminaires;
    - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
    - Revision of use of bridging capacitors in luminaires;